Сохраните в закладки:
*История изменения цены! Указанная стоимость возможно, уже изменилось. Проверить текущую цену - >
Месяц | Минимальная цена | Макс. стоимость | Цена |
---|---|---|---|
Sep-18-2025 | 1378.98 руб. | 1447.58 руб. | 1412.5 руб. |
Aug-18-2025 | 1366.45 руб. | 1434.77 руб. | 1400 руб. |
Jul-18-2025 | 1146.79 руб. | 1203.53 руб. | 1174.5 руб. |
Jun-18-2025 | 1343.6 руб. | 1410.11 руб. | 1376.5 руб. |
May-18-2025 | 1170.39 руб. | 1229.4 руб. | 1199.5 руб. |
Apr-18-2025 | 1320.20 руб. | 1386.99 руб. | 1353 руб. |
Mar-18-2025 | 1309.88 руб. | 1374.2 руб. | 1341.5 руб. |
Feb-18-2025 | 1297.0 руб. | 1362.21 руб. | 1329.5 руб. |
Jan-18-2025 | 1285.10 руб. | 1349.20 руб. | 1317 руб. |
Новые товары
Характеристики
Описание товара
Rated voltage: AC220V 50Hz/60Hz
Power consumption: <3W
Supply voltage: AC140V~320V
When the voltage current is normal the product will Automatic reconnect.
Leakage range: 10~99mA(adjustable)(Default 30mA) Leakage response time: ≤0.1S
Over voltage range: AC250~300V(adjustable)(Default 270V) Overvoltage response time: ≤0.1S
Low voltage range: AC150~190V(adjustable)(Default 170V) Low voltage response time: ≤0.1S
Over current range: 1~63A (adjustable) (Default 40A) Overcurrent range response time: ≤0.1S
Short-circuit current: ≥31ln Short-circuit response time: ≤0.1S
Error in real-time current, voltage and leakage current: ≤5%
PurposeIt is intended for a circuit of AC 50Hz/60Hz with maximum rated current of 63A to protect it and the equipment involved against overvoltage, low voltage, current surge, leakage, lightning, etc.
It is applicable to such electrical equipment as communication base stations, repeaters, video surveillance, Safety City, cable TV, digital TV, network switches, optical transceivers, meteorological telemetry stations, seismic detection stations in various conditions.
FeaturesDetection before closing: The automatic reclosing power protection switch monitors the circuit and will not close in occurrence of any overvoltage, leakage, overcurrent and other failures.
Overvoltage protection: When the voltage between the live wire and naught wire of the input terminal is greater than the set value, it will trip the switch for protection.
Low voltage protection: When the voltage between the live wire and naught wire of the input terminal is less than the set value, it will trip the switch for protection.
Overcurrent protection: When the actual current is greater than or equal to 1.15 times the rated current for 3 seconds, it will trip the switch for protection.
Leakage protection: When the leakage current exceeds the set value or an electric shock occurs, the automatic reclosing switch will be disconnected within 0.1 seconds to ensure personal safety.
Automatic disconnection when power's off: The switch will be automatically disconnected when the circuit is powered off, and will be automatically reclosed after detecting a normal power supply restored.
Intelligent leakage identification: Automatically detect before closing if the voltage is normal and the Neutral line is well-connected and never close in case of any failure.
Automatic reclosing: Automatically reclose after a certain time interval if the above failure occurs.
Automatically save tripping information: Automatically save such tripping information as tripping time, tripping type (cause), voltage, current and leakage current for failure analysis.
3.Main technical parameters
Rated voltage: AC220V 50Hz/60Hz
Power consumption: <3W
Supply voltage: AC150V~300V
Leakage range: 10~99mA Leakage response time: ≤0.1S
Overvoltage range: AC250~300V Overvoltage response time: ≤0.1S
Low voltage range: AC150~190V Low voltage response time: ≤0.1S
Overcurrent range: 1~63A Overcurrent range response time: ≤0.1S
Short-circuit current: ≥31ln Short-circuit response time: ≤0.1S
Error in real-time current, voltage and leakage current: ≤5%
Max. failure records: 999
Working conditions:
Temperature: -20°~55° Storage temperature: -45°~80°
Humidity: ≤95%Rh Atmospheric pressure: 70kPa~106kPa
Volume: 106X92X70mm
Wiring:you don't need to connect to GND, if you don't have GND
Note 1: This switch cannot be used as a master breaker. Please install a miniature circuit breaker as an overload short-circuiting fitting in front of the switch.
Note 2: Please adjust the current after installation.
Note 3: This product is designed without isolation function. Please disconnect the front breaker before repairing the circuit.
Заказала этот крутой костюм эльфа для косплея и новогодней вечеринки ? С нетерпением ждала эту посылочку и вот наконец-то получила... Читать отзыв полностью...
Отличный магазин для рыбаков. Взял тут спиннинг и набор снастей, персоналы помогли с тонкостями выбора, цена нормальная по рынку, доставка... Читать отзыв полностью...
Купила дочкам две такие коробочки, хранят там свои сокровища))) бусинки, бижутерию, поделки. Им очень нравится, и мне тоже, нигде ничего... Читать отзыв полностью...
Это платье заказала специально для похода на одну тематическую вечеринку. Скажу, что не была разочарована. Оно чудесное, плюс качество достаточно... Читать отзыв полностью...
Абсолютно не ясно, как подключить. Может кто прояснить ?... Читать отзыв полностью...
Это стильные серьги-гвоздики, скажу, что довольна своей покупкой на все сто процентов. Качество реально неплохое, если сказать вкратце. Также хочу... Читать отзыв полностью...
Купила этот датчик скорости и нисколько не пожалела. Стоимость его вполне адекватная оказалась, в других просто интернет-магазинах видела такой же... Читать отзыв полностью...