Сохраните в закладки:
*История изменения цены! Указанная стоимость возможно, уже изменилось. Проверить текущую цену - >
Месяц | Минимальная цена | Макс. стоимость | Цена |
---|---|---|---|
Sep-18-2025 | 0.16 руб. | 0.74 руб. | 0 руб. |
Aug-18-2025 | 0.0 руб. | 0.29 руб. | 0 руб. |
Jul-18-2025 | 0.73 руб. | 0.24 руб. | 0 руб. |
Jun-18-2025 | 0.96 руб. | 0.1 руб. | 0 руб. |
May-18-2025 | 0.17 руб. | 0.68 руб. | 0 руб. |
Apr-18-2025 | 0.96 руб. | 0.39 руб. | 0 руб. |
Mar-18-2025 | 0.87 руб. | 0.42 руб. | 0 руб. |
Feb-18-2025 | 0.80 руб. | 0.67 руб. | 0 руб. |
Jan-18-2025 | 0.72 руб. | 0.70 руб. | 0 руб. |
Новые товары
Характеристики
Описание товара
Purchase Notes:
1. If there are any technical problems before and after purchase, please consult directly if there are technical problems.
2. If you need the corresponding debugging software, agreement and instruction after purchase, you can contact the seller.
MODBUS Distributed Module Testing Software
Figure 1 MB8RO-relay output acquisition and control interface
Chapter I Product Introduction
I. Summary
MB8RO 8The output module of circuit relay can be controlled by MODBUS bus. The control interface is isolated RS485. Modbus-RTU communication is used to directly adapt to PLC, DCS and various domestic configuration software.
Relay output, power supply and RS485 communication electrical signals are isolated from each other, which can effectively suppress all kinds of serial and common mode interference, and also ensure the reliable operation of the module.
Two. Characteristic
1. Modbus-RTU protocol is adopted.
2. Relay output, power supply and RS485 communication electrical signals are isolated from each other.
3. RS485The output interface of communication signal adopts double protection of over voltage and over current.
4. Power polarity protection.
Three. Technical index
project
parameter
signal output
1Output Channel: 8 Frequently Open Relay Output
2Load capacity: resistance load 250V/10A inductive load 250V/3A
5. Relay coil and contact isolation voltage: 1500V
Communication output
1Communication protocol: MODBUS-RTU
2Interface type: isolated RS485 communication, output interface using over-voltage and over-current double protection
3Baud rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps, 19200 BPS
38400bps57600bps, 115200bps.
4Check bits: no check, even check, odd check
5Settings: Module address, baud rate, check bits through software settings
6Communication Distance: @9600bps 1200m
7. Isolation voltage: 1500V
Module size
Individual module size: 115mm*90mm*40mm
Installation mode
Installation of Standard DIN Guideway
work environment
Temperature: - 10 ~ + 55 C Humidity: 35 ~85% (No dew)
Working power supply
1Power supply voltage: 10V~30V wide range power supply, with power supply polarity protection
2Power consumption: less than 3W
Four. Product appearance
Five. Peripheral wiring diagram
1. Relay Output Connection Method
2. Connection of communication and power supply
Six. Module Indicator and Switching Function Description
1. POW/SET; Module working status indication
A.Green light: The module is in operation. B. Red light: Module has configuration parameters written, need to re-power.
2. TXD/RXD: Communication status indication
A.Green light flashes: communication receives data B. Red light flashes: module is sending data
C.Green lights are always on: DATA + and DATA - connected communications RS485 wiring is reversed or disconnected.
3. Module right reset switch
1) When the communication parameters (module address, baud rate, check bit) are not known or the communication parameters are set incorrectly, the solution is to reset the communication parameters; we hold the reset switch with the clip and do not open it. Five seconds later, the module [POW/SET] red indicator lights up and the reset switch is opened. At this time, the communication parameters have been reset, as long as the power supply of the module is cut off. After restarting, the communication parameters of the module have been reset.
2) Communication parameters after reset: address: 1, baud rate: 9600 bps, check bit: No.
Seven. Schematic block diagram
Eight. MODBUSRegister description
1. MODBUS Function Codes Supported by Modules
Code
Meaning
operation
0x01H
Read multiple coil registers
Read the value of one or more coil registers
0x03H
Read multiple hold registers
Read the value of one or more holding registers
0x05H
Write a coil register
Write the value of a coil register
0x 06H
Write a single hold register
Write a data to the hold register
0x0FH
Write one or more coil registers
Write the value of one or more coil registers
0x 10H
Write multiple hold registers
Write one or more data to the hold register
2. Register Definition Description
1) Coil Register(0x01H,0x05H,0x0FH)
address
parameter
read/write
minimum value
Maximum value
Explain
00001
RO0
Read and write
0
1
Relay output0
00002
RO1
Read and write
0
1
Relay output1
00003
RO2
Read and write
0
1
Relay output2
00004
RO3
Read and write
0
1
Relay output3
00005
RO4
Read and write
0
1
Relay output4
00006
RO5
Read and write
0
1
Relay output5
00007
RO6
Read and write
0
1
Relay output6
00008
RO7
Read and write
0
1
Relay output7
2) Keep Register(0x03H,0x06H,0x10H)
address
parameter
read/write
minimum value
Maximum value
Explain
40065
Equipment type
read-only
0
256
2 (MB8ROModule)
40066
Device status
read-only
0
0x0101
Bit4Reset button status
Bit0Module Reset Request Flag
40067
Module voltage
read-only
0
300
0.0-29.9V
40069
product version
read-only
0
65535
Hardware version(high8position) + Software version(low8position)
40070
production information
read-only
0
65535
year(high8position) + Batch number(low8position)
40071
Module address
read/write
1
247
1(default)
40072
baud rate
read/write
0
7
0(1200) 1(2400) 2(4800) 3(9600) default4(19200) 5(38400) 6(57600) 7(115200)
40073
Parity bit
read/write
0
2
0(No check.) default 1(Parity check) 2(Odd parity check)
Абсолютно не ясно, как подключить. Может кто прояснить ?... Читать отзыв полностью...
Здравствуйте, можно ли приобрести отдельно комплект проводов для подключения андройд устройства БМВ е60 ССС?... Читать отзыв полностью...
Отличные часы, заказала сразу пять штук на подарки своим друзьям и родственникам. Не пожалела о своей покупке. Цвет интерсеный, качество... Читать отзыв полностью...
Товар пришел быстро,что очень меня порадовало. Перчатки очень хорошие, качество отличное ,теплые,мягкие,удоб ные. Полностью соответствуют ,как на картинке,даже круче. О... Читать отзыв полностью...
Это стильные серьги-гвоздики, скажу, что довольна своей покупкой на все сто процентов. Качество реально неплохое, если сказать вкратце. Также хочу... Читать отзыв полностью...
Забавная маска, довольно страшная. Цена не высока, по размерам угадали. Главное в маске, эффект неожиданности. Шутка удалась. Для маскарада и... Читать отзыв полностью...