Сохраните в закладки:
*История изменения цены! Указанная стоимость возможно, уже изменилось. Проверить текущую цену - >
Месяц | Минимальная цена | Макс. стоимость | Цена |
---|---|---|---|
Sep-14-2025 | 42259.27 руб. | 44372.25 руб. | 43315.5 руб. |
Aug-14-2025 | 41904.51 руб. | 43999.12 руб. | 42951.5 руб. |
Jul-14-2025 | 35157.95 руб. | 36915.67 руб. | 36036 руб. |
Jun-14-2025 | 41194.4 руб. | 43254.48 руб. | 42224 руб. |
May-14-2025 | 35867.63 руб. | 37660.64 руб. | 36763.5 руб. |
Apr-14-2025 | 40484.39 руб. | 42508.83 руб. | 41496 руб. |
Mar-14-2025 | 40129.94 руб. | 42135.65 руб. | 41132 руб. |
Feb-14-2025 | 39773.43 руб. | 41762.6 руб. | 40767.5 руб. |
Jan-14-2025 | 39418.53 руб. | 41389.29 руб. | 40403.5 руб. |
Новые товары
Характеристики
Описание товара
Specifications & Features
Large measure range.
High precision.
Automatic Temperature Compensation ( ATC ).
Close ATC function.
All series of zero calibration function with distilled water. (Include NR111 45.0%-95.0%Brix)
Measure any solution’s refractive index under different temperatures.
Centigrade & Fahrenheit measurements
Models
Type
Range
Resolution
Accuracy
LDR400
BRIX
45.0-95.0%
0.1%
±0.1%
nD
1.4098--1.5318
0.0001
±0.0002
WATER
38.0--5.0%
0.1%
±0.1%
BDR500
BRIX
0.0-95.0%
0.1%
±0.1%
nD
1.3330--1.5318
0.0001
±0.0002
C.S.1
C.S.2
All Models
5-80'C
0.1'C
±1'C
Temperature
'F
0.1'F
±2'F
Automatic shut off after 3 minutes
Instantaneous reading
Battery level display
Tolerance limit alarm function.
Stainless steel sample plate
Operation humidity: lower than 90%.
Operation sea level: lower than 2000m.
Operation temperature: 0 'C ( 32 'F) - 40 'C ( 104'F).
Storage temperature: -10'C ( 14 'F ) - 50'C ( 122 'F).
Operating time: more than 5000 times per battery.
Power supply: 9V Alkaline Battery
Weight: 900g
Dimensions:180mm×100mm×60mm
PrecautionsThis refractometer is an electronic instrument – it can become damaged if dropped or handled in a rough manner.
The prism is made of optical glass and is susceptible to scratches – do not apply any rough or abrasive material and take care when cleaning the prism.
After each use, clean the prism & prism assembly with a soft cloth or tissue soaked in water and wipe off with a dry cloth or tissue.
Do not hold the refractometer under a stream of water from a faucet. Do not splash it with or dip it in water.
If the surface of the prism becomes coated with an oily solution or similar, it will repel test sample and
affect readings. If this occurs, the prism should be cleaned with a weakened detergent or similar solvent.
Do not leave instrument under direct sunlight or in a vehicle on a sunny day.
Do not use an instrument unless you have personal knowledge of calibration.
Automatic Temperature Compensation (ATC)
Automatic-temperature-compensation insure that concentration reading of aqueous (water
based) solution will be accurate with respect to the sample’s temperature.
This digital refractometer is able to automatically correct for differences in the temperature of the sample to a reference
temperature, usually 20'C. It is well know that substantially all materials expend when heated (become less dense) and
contract when cooled (become more dense). The speed of light in a liquid increases with temperature,
and the refractive index therefore decreases. Although this thermal effect is small for solids,
the change in density for liquids is substantial. For example, the reading for a sucrose solution will change
by approximately 0.5 Brix for each 10'F(5'C) change in temperature. So a 10 Brix solution read at 42'C(108'F)
would read 8 Brix on a non-temperature compensated instrument. Many hand-held refractometers are not temperature
compensated and require the user to manually take temperature measurements and apply a correction.
Other hand-held refractometers offer only rudimentary compensation in the range of 18'C(65'F) to 35'C(95'F).
This digital refractometer can automatically compensate for temperature differences within the range 5'C to 40'C.
For the most accurate possible readings the instrument, the ambient temperature and the fluid should be
in equilibrium within this temperature range. When testing a sample with a temperature that deviates a great deal
from the temperature of the instrument. It may be necessary to put the instrument and the fluid in the same environment
for some time. A good rule is to wait approximately 30 minutes for each 10'F(5'C) difference in temperature
in order to conduct measurement after keeping the instrument, fluid to be tested and environment in the same temperature.
Confirmation of PackagePlease confirm the following contents of the package immediately when the Unit is unpacked.
Instruction Manual ……………… 1 bottle of distill water ……………… 1 battery ( 9 v ) ……………….. 1
Leatheroid carried bag ……….. 1 burette …………………………….. 1
Отличные часы, заказала сразу пять штук на подарки своим друзьям и родственникам. Не пожалела о своей покупке. Цвет интерсеный, качество... Читать отзыв полностью...
Извините, как зовут женщину на прикрепленной фотографии?... Читать отзыв полностью...
От магазина один негатив! Товар не получил! Прошло 9 месяцев! Все споры закрыл сам магазин! Обещал 30 раз повторные поставки... Читать отзыв полностью...
Качество порадовало, плюс довольно модная и вместительная. Ценник свои оправдывает. Рекомендовать могу смело, Как доставили, качество оценил, брака не выявил,... Читать отзыв полностью...
Сделала покупку у данного продавца впервые. Купила на свой страх и риск два комплекта сразу: для мальчика и девочки. Ткань-... Читать отзыв полностью...
Нисколько не пожалела, что заказала здесь светоотражающий Зонт Godox. СТоимост оказалась вполне доступной. Просто в других интернет-магазинах видела такой же... Читать отзыв полностью...
Серьги просто замечательные, по-другому и не скажешь. Я была удивлена, когда их получила. Они выглядят даже круче, чем на фото.... Читать отзыв полностью...